Vision panels in fire doors building regulations.
If it is covered then it is no longer a vision panel.
Building regulations fire doors are required in almost every building built in the uk according to the requirements of the relevant national fire safety regulations.
Allowing people using the door to be seen vision panels should be towards the leading edge and with vertical dimensions including at least the minimum zones shown either with or without a horizontal rail.
Building regs approved document b requires vision panels in doors so that you can see if there are signs of fire on the other side.
Note also the provision in approved document m access to and use of buildings concerning vision panels in doors across accessible corridors.
Vision panels may be reduced in size or omitted on internal doors where privacy light control or security is a requirement on sanitary accommodation changing rooms or cinemas and auditoria for example.
Approved document m states that where appropriate in door leaves or side panels wider than 450mm vision panels towards the leading edge of the door have vertical dimensions which include at least the minimum zone of visibility between 500mm and 1500mm from the floor if necessary interrupted between 800mm and 1150mm above the floor e g.
As 1530 methods for fire tests on building materials components and structures part 1.
Building work at all new schools must conform to building bulletin 100.
Building regulations for fire safety in residential homes including new and existing dwellings flats residential accommodation schools colleges and offices.
Unless it can be argued otherwise in the access statement e g.
English and welsh building regulations are divided into parts with.
1993 test for flammability of materials c3 1 1 c4 1 1 part 4.
The regulations recommend that fire doors have vision panels to assist movement around the school and to accurately assess whether a door is containing smoke and fire.
Vision panels are needed where doors on escape routes sub divide corridors or where any doors are hung to swing both ways.
Where required vision panels glazed apertures should be fitted between 500 mm and 1500 mm from the top.
Eg in the door to an inner room so the occupant s can see if there are signs of fire in the outer room.
For reasons of security door leaves and side panels wider than 450mm have vision panels towards the leading edge of the door whose vertical dimensions include at least the minimum zone or zones of visibility between 500mm and 1500mm from the floor if necessary interrupted.
2005 fire resistance tests of elements of construction c6 1 1 as 1691.
Design for fire safety in schools which has a section of information dedicated to school fire doors.
1994 combustibility test for materials c5 1 1 part 2.