Restaurant refrigeration parts supply walk in cooler parts refrigerator parts oven range parts.
Walk in freezer drain line heater.
And should never insulate the drain line and tape with armaflex.
Coil around outside of drain line and insulate with armaflex pipe insulation.
In addition to these items we sell defrost and drain line heaters along with heater blankets to meet your needs.
These drain line heaters are used in the refrigeration industry for freeze protection of drain pipes and for condensate in the drain pan.
Than i see the black drain line heater wraped around the outside of a 3 4 pvc drain.
We provide a wide variety of.
Excellent price and problem solved.
Standard emperature for freezers is 10 f.
True drain line heater wire for true freezer equipment in stock same day shipping.
A friend showed me his walk in with overflowed frozen drain pan and losts of ice on the floor below.
I ve only worked on a hand ful of walk in freezers and i guess i never paid much attention to the drain lines before.
801805 drain tube heater 115 volt for over 65 years true refrigeration has been an industry leader in commercial refrigeration and has maintained high standards.
This was a service call on a walk in freezer drain that was leaking water all over the floor i found that the drain line had frozen and split in several sec.
Thick foamed in place urethane.
Always clean with the polish lines.
You still require a drain trap.
Flexdrain drain line heaters include a heating part and a cold power cable at one end.
Also make sure to check out other great items from avantco ice machines avantco refrigeration beverage air aht cooling systems aladdin all points and atlas metal industries inc.
This might sound like a stupid question but i have to ask.
I used this one and it fits perfect the plug is the same length and size everything.
Use with a 3 4 thick copper pipe with an approximate length of 6.
W self closing door with two spring loaded.
Extremely flexible these drain heating cables are quick safe and easy to use.
I used this on a traulsen refrigerator freezer that had a drain line freezing up.
Pvc drain line doesent conduct heat well so it is a poor choice in the walk in freezer application.
Traulsen wanted 200 for their part.
Drain line heater wire 12 length 230vac 40 watt.
Master bilt 17 09290 drain line heater 240v.
Wire can melt pvc.
Make sure drain pipe is sloped for proper drainage.
It doesent help thaw out the drain line durring defrost but will start one hell of a smoky fire should the tape fail from a short.
Crank case and drain line heater.